一、 Product overview
The product is mainly used to detect the internal defects, structural dimensions, consolidation grouting compactness and other items of concrete in tunnel lining (subway segment, etc.), which can describe the general shape and distribution of defects.

二、 Scope of application
It can be used to detect internal defects of concrete in tunnel lining (subway segment, etc.).

三、Product advantage
1, convenient operation, high test accuracy;
2, small impact by reinforcement;
3, not affected by concrete structure form;
4, intelligent human-computer interaction function, so that the detection work more sense of science and technology;
5, plane imaging, intuitive presentation of defects, void distribution;

四、 Instrument parameters
1. Platform: integrated platform;
2. Operating system: Windows
3. Signal transmission mode: wired transmission;
4. Noise processing: smoothing, filtering, BPF, EMD and other functions;
5. Analysis and treatment methods: FFT (EFS) /MEM;
6. Test content: concrete material, defect, void, size detection;
7. Test method: Impact echo method (IE);
8. Can receive signal channel number: 2 channel, two channel function is interchangeable, can be as the trigger channel as a receiving channel;
9 working temperature: -30 ~ 50℃;
10.*Sampling accuracy: the comprehensive performance is not less than 24 bits;
11.* Maximum acquisition frequency: not less than 1000KHz, and adjustable;
12. * minimum sampling interval: 1 us, adjustable;
13. Test signal: vibration signal;
14. Statistical processing: average and deviation processing;
15. Signal processing: integral processing, spectrum analysis, correlation analysis;
16. Signal input mode: dual channel supports BOTH IEPE and DC, and dual channel can be used at the same time
17 signal zoom/zoom: test waveform support mouse zoom;
18. Frequency response range: 1khz-40khz;
19. Dynamic range: 60dB;
20. Resonance frequency of sensor system: 60KHz;
21. System noise: less than 20μ V;
22. Relative amplitude error of the detection system: less than 1%;
23. Relative error of sound signal measurement: less than 0.5%;
24. Error: less than 0.5%.

 